{"product_id":"sw®-powerchem®-pc-12wt1000-ecotek®-sustainable-nitrile-cleanroom-gloves-12-100ct","title":"SW® PowerChem® PC-12WT1000 EcoTek® Sustainable Nitrile Cleanroom Gloves, 12\", 100ct","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eSW® PowerChem® PC-12WT1000 EcoTek® Sustainable Nitrile Cleanroom Gloves are designed for controlled environments requiring reliable durability, chemical resistance, and particulate control. These high-performance nitrile cleanroom gloves provide extended coverage and protection for medical device manufacturing, precision electronics, semiconductor assembly, pharmaceutical, aerospace, and laboratory applications.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe PC-12WT1000 is designed for \u003cstrong\u003eClass 1000 \/ ISO 6 cleanroom environments\u003c\/strong\u003e and features a 12-inch extended cuff for additional wrist and forearm coverage. The finger-textured surface provides reliable grip in wet and dry conditions, while the optimal thickness supports a balance of durability and tactile sensitivity.\u003c\/p\u003e\n\u003cp\u003eThe gloves use \u003cstrong\u003evacuum-packed packaging\u003c\/strong\u003e to help reduce storage space, protect gloves from contamination, and minimize packaging waste. Low Dermatitis Potential (LDP) helps minimize the risk of Type I and Type IV allergies and supports users with sensitive skin.\u003c\/p\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEcoTek® Sustainable Technology\u003c\/li\u003e\n\u003cli\u003ePowder-free nitrile cleanroom gloves\u003c\/li\u003e\n\u003cli\u003eClass 1000 \/ ISO 6 cleanroom compatible\u003c\/li\u003e\n\u003cli\u003e12-inch extended cuff for added coverage\u003c\/li\u003e\n\u003cli\u003eFinger-textured surface for wet and dry grip\u003c\/li\u003e\n\u003cli\u003eVacuum-packed packaging\u003c\/li\u003e\n\u003cli\u003eDesigned to reduce storage space\u003c\/li\u003e\n\u003cli\u003eHelps protect gloves from contamination\u003c\/li\u003e\n\u003cli\u003eLow Dermatitis Potential\u003c\/li\u003e\n\u003cli\u003eOptimal thickness for durability and tactile sensitivity\u003c\/li\u003e\n\u003cli\u003eTear-resistant beaded cuff\u003c\/li\u003e\n\u003cli\u003eAmbidextrous design\u003c\/li\u003e\n\u003cli\u003e6.2-mil finger thickness\u003c\/li\u003e\n\u003cli\u003e5.0-mil palm thickness\u003c\/li\u003e\n\u003cli\u003e4.0-mil cuff thickness\u003c\/li\u003e\n\u003cli\u003e1.5 AQL\u003c\/li\u003e\n\u003cli\u003eWhite color\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMedical device manufacturing\u003c\/li\u003e\n\u003cli\u003ePrecision electronics\u003c\/li\u003e\n\u003cli\u003eFiber optics\u003c\/li\u003e\n\u003cli\u003eSemiconductor assembly\u003c\/li\u003e\n\u003cli\u003eOptical applications\u003c\/li\u003e\n\u003cli\u003eAerospace component manufacturing\u003c\/li\u003e\n\u003cli\u003ePharmaceutical packaging\u003c\/li\u003e\n\u003cli\u003eCosmetics production\u003c\/li\u003e\n\u003cli\u003eLaboratory testing\u003c\/li\u003e\n\u003cli\u003eISO 6 controlled environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCleanroom Performance\u003c\/h3\u003e\n\u003cp\u003eThe PC-12WT1000 is classified as \u003cstrong\u003eClass 1000 \/ ISO 6\u003c\/strong\u003e cleanroom compatible. The datasheet reports a particle count of less than 3,000 counts\/cm² for particles ≥0.5 micrometer.\u003c\/p\u003e\n\u003cp\u003eTesting also reports controlled ionic residue levels, with silicone, amide, and dioctyl phthalate (DOP) listed as not detected.\u003c\/p\u003e\n\u003ch3\u003eEcoTek® Sustainable Technology\u003c\/h3\u003e\n\u003cp\u003eEcoTek® gloves are tested by an independent laboratory for anaerobic biodegradation potential under accelerated landfill conditions. The datasheet reports 92.6% biodegradation in 60% solids landfill conditions at 945 days. Future results cannot be predicted or extrapolated.\u003c\/p\u003e\n\u003ch3\u003ePackaging\u003c\/h3\u003e\n\u003cp\u003eEach size contains \u003cstrong\u003e100 gloves per bag and 10 bags per case\u003c\/strong\u003e. The gloves use vacuum-packed packaging for controlled storage and contamination protection.\u003c\/p\u003e","brand":"SW® Sustainable Solutions","offers":[{"title":"S (6.5–7)","offer_id":54042155581756,"sku":"PC-12WT1000-S","price":28.75,"currency_code":"USD","in_stock":true},{"title":"M (7.5–8)","offer_id":54042155614524,"sku":"PC-12WT1000-M","price":28.75,"currency_code":"USD","in_stock":true},{"title":"L (8.5–9)","offer_id":54042155647292,"sku":"PC-12WT1000-L","price":28.75,"currency_code":"USD","in_stock":true},{"title":"XL (9.5–10)","offer_id":54042155680060,"sku":"PC-12WT1000-XL","price":28.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0743\/7562\/7068\/files\/PC-12WT1000.png?v=1787918068","url":"https:\/\/eco-mdsassociates.com\/products\/sw%c2%ae-powerchem%c2%ae-pc-12wt1000-ecotek%c2%ae-sustainable-nitrile-cleanroom-gloves-12-100ct","provider":"MDS Associates USA","version":"1.0","type":"link"}